Home / Drywall takeoff
Quantity takeoff · Drywall
Drywall takeoffs from your plan set
Square feet of board by type and thickness, linear feet of trims and bead, and openings counted, organized by area and traced to the sheet they came from. For Florida contractors and drywall subs bidding residential and light commercial work.
What gets counted
Quantities, units and the sheets they come from.
- Board
- SF by type and thickness (for example 1/2 in. regular, 5/8 in. Type X, moisture-resistant, cement board where drawn), split by wall type and area. From the floor plans, wall-type legend and sections.
- Ceilings
- SF by ceiling type and height from the reflected ceiling plan. Soffits and bulkheads are listed as their own rows.
- Trims
- LF of corner bead, J-bead or L-bead and control joints where the drawings show them.
- Openings
- EA by size, deducted from wall area. Areas are net as drawn unless you state another rule.
- Heights
- Taken from sections and interior elevations. A height that isn't dimensioned becomes a question.
Illustrative sample
What the rows look like
| Item | Location | Sheet ref | Qty | Unit | Note |
|---|---|---|---|---|---|
| Drywall, 1/2 in. regular | Level 1 interior walls | A-201 | 1,840 | SF | Both faces where shown |
| Drywall, 5/8 in. Type X | Garage separation wall | A-201 | 312 | SF | Wall type W3 |
| Drywall, 1/2 in. moisture-resistant | Bathrooms 1 and 2 | A-201 | 264 | SF | Per finish schedule |
| Corner bead, metal | Level 1 | A-101 | 148 | LF | Outside corners as drawn |
Swipe the table sideways to see every column
Questions log · illustrative
- Q-01 · A-201 · Wall type W3 height is not dimensioned. Confirm 9'-0" before the final takeoff.
- Q-02 · A-501 · The kitchen soffit ceiling type differs between the reflected ceiling plan and the section. Which governs?
Fictional plan set and quantities shown for demonstration only, not a client project. Anything unclear in the drawings is listed as a question for you, not guessed.
How it's measured
Counted from the documents. Traced to the sheet. Questions, not guesses.
01 Net as drawn
Areas are measured net of openings with no waste added. Your waste factor goes in your estimate, where you control it.
02 By wall type
Each wall type in the legend gets its own rows, so a 5/8 in. Type X separation wall never blends into the 1/2 in. partitions.
03 Faces as detailed
One face or two follows the wall-type detail. Where the detail doesn't say, it goes on the questions list.
What stays with you
Your prices. Your estimate.
Board prices, sheet layout and waste, labor and markup stay with you. We don't select fire-rated assemblies or decide where Type X board is required: we count what the wall-type legend and plans show.
Scope: reading and quantifying what is drawn, item counts, measurements, and organized lists. Not engineering judgment, not structural calculation, not code compliance review, and not a substitute for a licensed engineer's seal where one is required.
Other trades
FAQ
Common questions
Square feet, net as drawn, by type and thickness. Converting to sheets depends on your layout and waste practice, so that stays in your estimate. If you want a sheet count at a stated sheet size, ask for it in your scope and it is listed as a separate, labeled row.
Yes, when the plans identify it. Each wall and ceiling type in the legend gets its own rows. We don't decide where a rated assembly is required; if a wall type is unclear in the plans, it goes on the questions list.
The architectural set: floor plans, reflected ceiling plans, wall-type legend, sections and finish schedule, plus any addenda. A link to the PDFs is enough.
Yes, if they are in the scope you send. Ceilings are measured from the reflected ceiling plan by type, and soffits and bulkheads are listed separately so you can price them at their own rate.
Plans first · Scope review before quote
Bidding drywall? Send the plans.
Scope, turnaround and a fixed price are confirmed with you after the plans are reviewed. Sending them doesn't commit you to anything.